\rJR2008-A<\/strong>型自動(dòng)<\/strong>96/384<\/strong>孔微孔板清洗機(jī)<\/strong><\/div>\rJR2008-A型自動(dòng)96/384孔微孔板清洗機(jī)JR2008-A型自動(dòng)96/384孔微孔板清洗機(jī)是由上海精睿生物科技發(fā)展有限公司于2008年隆重推出的新一代多功能的微孔反應(yīng)板清洗機(jī)器,由微電腦控制,能夠自動(dòng)完成多種規(guī)格的96孔和384孔酶標(biāo)微孔反應(yīng)的清洗工作,是進(jìn)行酶聯(lián)免疫吸附實(shí)驗(yàn)(ELISA)必不可少的設(shè)備,可廣泛用于從事生命科學(xué)研究工作的科研院所,高等院校以及醫(yī)院、血站、疾病控制中心等單位。<\/div>\r主要特點(diǎn):<\/div>\r一、既能清洗384孔板,也能清洗96孔板(包括平底、U形底和V型底);<\/div>\r二、中文菜單操作,鍵盤(pán)編輯,大屏幕液晶顯示;<\/div>\r三、清洗方式分為板式清洗和條式清洗兩種方式,滿足不同用戶(hù)的清洗需求;<\/div>\r四、清洗時(shí)可只清洗奇數(shù)排或偶數(shù)排或每排都清洗,滿足不同用戶(hù)的清洗需求;<\/div>\r五、具有振蕩與浸泡功能,有利于降低反應(yīng)過(guò)程中的干擾性吸附;<\/div>\r六、可調(diào)節(jié)清洗頭的高度,以滿足不同高度的酶標(biāo)板;<\/div>\r七、8、12、16、24道清洗頭能互相置換,安裝方便;<\/div>\r八、具有洗板程序存貯功能,可以存貯20個(gè)用戶(hù)自定義的洗板程序;<\/div>\r九、帶RS-232電腦接口。<\/div>\r <\/div>\r主要技術(shù)指標(biāo):<\/strong><\/div>\r一、清洗方式:?jiǎn)闻艞l洗、雙排條洗、逐排條洗、單排板洗、雙排板洗、逐排板洗;<\/div>\r二、清洗頭:8、12、16、24通道;<\/div>\r三、清洗條數(shù):96孔板:1—2排可調(diào),<\/div>\r 384孔板:1—24排可調(diào);<\/div>\r四、清洗容量:96孔板:50—500μl,<\/div>\r 384孔板:50—100μl<\/div>\r五、清洗次數(shù):1—20次;<\/div>\r六、暫停時(shí)間:0—60秒;<\/div>\r七、浸泡時(shí)間:0—250秒;<\/div>\r八、吸液時(shí)間:100-10000毫秒;<\/div>\r九、清洗液殘留量:≤2μl /孔;<\/div>\r十、存儲(chǔ)容量:可存儲(chǔ)20種參數(shù)程序<\/div>\r <\/div>\r售后服務(wù):三年保修,終生服務(wù)<\/div>\r <\/div>\r精睿<\/strong>384<\/strong>孔板特點(diǎn):<\/strong><\/div>\r一、 高通量(384孔),可以同時(shí)進(jìn)行多達(dá)384個(gè)并行分析實(shí)驗(yàn);<\/div>\r二、 微型化(80微升/孔),進(jìn)行ELISA 實(shí)驗(yàn)時(shí),需要的標(biāo)本和試劑量?jī)H為96孔板的1/4,可以節(jié)省75%的試劑及標(biāo)本費(fèi)用;<\/div>\r三、 使用方便(易拆),可以根據(jù)實(shí)驗(yàn)數(shù)量需求進(jìn)行拆裝,滿足不同客戶(hù)的需要;<\/div>\r四、 種類(lèi)齊全,無(wú)色透明板條用于常規(guī)ELISA,黑色板條用于化學(xué)發(fā)光實(shí)驗(yàn),白色板條用于免疫熒光實(shí)驗(yàn)。<\/div>\rJR2008—A型自動(dòng)96/384微孔板清洗機(jī)的特點(diǎn):<\/div>\r能夠清洗各種96孔和384孔微孔反應(yīng)板。!<\/div>\r <\/div>\r <\/div>\r <\/div>\rP2:<\/strong><\/div>\rEnzyme-Linked Immunosorbent Assay (ELISA) is a immunoenzymatic technique developed after the invention of immunofluorescence technique and radioimmunology technique.<\/div>\r <\/div>\rELISA is a high sensitivity assay technique, based on the principles of immune reactions that combine specialized immune reaction and enzyme’s high catalyzing efficiency.<\/div>\rThe immune reaction is happened on a solid-phase, the polystyrene micro plates, so after every time a reagent is loaded and incubated, the rest reactant can be washed away, as the result, the specificity and stability are guaranteed. In the real application, there are several different methods which are indirect ELISA used to determination **body, paired-**bodies sandwich ELISA used to determination **gen and **gen competitive ELISA used to determination the low-molecular-weight **gen or hapten.<\/div>\r <\/div>\rThe most frequently used carrier of ELISA is microtiter-plates. Some microtiter-plates specifically used in ELISA are called ELISA plates. The international standard micro titer-plates are composed of 8 lines, 12 arrays, 96 wells. Every wells has a volume of 400 μl. The samples and reagents’ volume are often about 100-200 μl. There is 8/12 wells strip invented to make it easy to determine small-amount sample. These strips are fit with the ELISA plate frame just as ELISA plates. The feature of ELISA plates is that you can determinate large-amount samples and you can read out the results directly by the colorimeter. Now, there have been many kinds of auto-instruments, which can sample, wash, and heat insulate and colorimetric, used to read ELISA plates. It’s much beneficial to the operational standardization.<\/div>\r <\/div>\r <\/div>\r圖釋 96 wells microplates and strips 384 wells micro plates and strips<\/div>\r <\/div>\r <\/div>\rTo meet the demands of high efficient assay in gene, protein and drug research, to reduce the reagent and cost, micro titer-plate’s wells are made more and more smaller and denser, so, nowadays, the basic well-amount is 384/1536, every well’s capacity is reduced to 100/20μl. Thus, the reagent can be reduced to 40/10μl to finish one determination. Till now, all the 384/1536 microplates is in one piece, so it can only be used to determinate large-amount samples to avoid wasting.<\/div>\rOver many years’ elaborately study, Shanghai GenoMintel Bioscience & Technology Development Co., Ltd invented the following products (with the independent intellectual property rights):<\/div>\r <\/div>\r <\/div>\rP3:<\/strong><\/div>\rA detachable 384 wells microplate.<\/strong><\/div>\rThe 384 wells ELISA plates have a great advantage in high-throughput and miniaturization application, so they are mainly used in drug screening, genomics and proteomic research, which are large-scale research and produce large amount of experimental data.However, in ordinary ELISA, not all 384 wells are used, so 384 wells microplates have not been popularized.<\/div>\rGenoMintel’s “detachable 384 wells microplates” solved this problem. No matter how much sample you have, you can use this kind microplates to run your ELISA. Because of the low capacity of the wells, compare with the 96 wells microplates, you can save 75% of your sample and reagent in the condition of having a same result. This “detachable 384 wells microplates” are divided into transparent strips used to run ordinary ELISA, black strips used to run chemiluminescence enzyme immunoassay and white strips used to run fluerescence immunoassy.<\/div>\rA frame and strips composes this detachable 384 wells microplate. Every strip has 16 splitable wells. 24 strips compose a 384 wells microplate in the frame. Thus, users can use as many wells as he want.<\/div>\r <\/div>\r <\/div>\r圖釋transparent strips used to run ordinary ELISA<\/div>\rblack strips used to run chemiluminescence enzyme immunoassay<\/div>\rwhite strips used to run fluerescence immunoassy<\/div>\r <\/div>\r <\/div>\rP4:<\/strong><\/div>\rType JR2008-A 96/384 wells auto microplate-washer<\/strong><\/div>\rType JR2008-A 96/384 wells auto microplate-washer was a new generation multifunction microplate-washer pushed out by GenoMintel in 2008. It is controled by microcomputer and can wash 96/384 wells microplates automatically.<\/div>\rJR2008 is an irreplacable instrument in ELISA and has a wide application in biology institutes, universities, bloodbank, CDC,etc..<\/div>\rMain feature:<\/div>\r1. Washes 96/384 wells microplates and strips (include U-buttom and V-buttom)<\/div>\r2. Chinese-English operation manu, programming with keyboard, large LCD display<\/div>\r3. There are two wash mode to meet different needs:plate washing mode and strip washing mode<\/div>\r4. Washes only odd lines or even lines<\/div>\r5. Reduce interfering absorbtion by immersion and shaking<\/div>\r6. To fit different microplate-reader, the height of wash heads is ajustable<\/div>\r7. The 8/12/16/24 channel wash heads are inter-replaceable and convenient mounting.<\/div>\r8. Storages 20 user-defined washing programs<\/div>\r9. With RS-232 interface<\/div>\r圖釋 12 channel heads 24channel heads<\/div>\r 8 channel heads 16channel heads<\/div>\r <\/div>\r <\/div>\rP5:<\/strong><\/div>\rMain technical index<\/strong><\/div>\r1. washing mode: washing strip by single line,<\/div>\rwashing strips by double line,<\/div>\rwashing strips line by line.<\/div>\rwashing plate by single line,<\/div>\rwashing plate by double line,<\/div>\rwashing plate line by line.<\/div>\r2. washing head: 8/12/16/24 channels<\/div>\r3. washing lines: for 96 wells microplates: 1-12 lines, ajustable<\/div>\r for 384 wells microplates: 1-24 lines, ajustable<\/div>\r4. washing capasity: for 96 wells microplates: 50-500μl<\/div>\r for 384 wells microplates: 50-100μl<\/div>\r5. wash times: 1-20<\/div>\r6. pause time: 0-60s<\/div>\r7. immerse time: 0-250s<\/div>\r8. suck time: 100-10,000 ms<\/div>\r9. washing liquid residue: ≤2μl / well<\/div>\r10. storage: 20 programes<\/div>\r圖釋:washing 96 wells microplates washing 384 wells microplates<\/div>\r <\/div>\rAfter salse service<\/strong><\/div>\rWe provide guarantee repair for three years after your purchase.<\/div>\r <\/div>\r<\/div><\/div>
|