沈陽市DACO接觸器DCP-21HI020,DCP-21HI030,DCP-21HI050,中山立訊電氣有限公司銷售韓國POWERPLAZA開關(guān)電源價格優(yōu)惠
No
|
Images
|
Model
|
Safety
|
DATA
|
Vin
|
Vout
|
Iout
|
Outputs
|
Price
|
Status
|
8
|
|
SPTS15-24-3R3
|
|
|
10 ~ 36V
|
3.3V
|
4.00A
|
single
|
$24.35
|
Sale
|
7
|
|
SPTS15-48-15
|
|
|
20 ~ 72V
|
15V
|
1.00A
|
single
|
$23.81
|
Call
|
6
|
|
SPTS15-48-12
|
|
|
20 ~ 72V
|
12V
|
1.25A
|
single
|
$23.81
|
Sale
|
5
|
|
SPTS15-48-5
|
|
|
20 ~ 72V
|
5V
|
3.00A
|
single
|
$23.81
|
Sale
|
4
|
|
SPTS15-48-3R3
|
|
|
20 ~ 72V
|
3.3V
|
4.00A
|
single
|
$23.81
|
Call
|
3
|
|
SPTS15-24-15
|
|
|
10 ~ 36V
|
15V
|
1.00A
|
single
|
$24.35
|
Sale
|
2
|
|
SPTS15-24-12
|
|
|
10 ~ 36V
|
12V
|
1.25A
|
single
|
$24.35
|
Sale
|
1
|
|
SPTS15-24-5
|
|
|
10 ~ 36V
|
5V
|
3.00A
|
single
|
$24.35
|
Sale
|
總之,只有了解用戶、了解任務(wù)才能設(shè)計出好的人機(jī)界面。確定為完成此系統(tǒng)功能人和計算機(jī)應(yīng)分別完成的任務(wù)任務(wù)分析有兩種途徑。一種是從實(shí)際出發(fā),通過對原有處于手工或半手工狀態(tài)下的應(yīng)用系統(tǒng)的剖析,將其映射為在人機(jī)界面上執(zhí)行的一組類似的任務(wù);另一種是通過研究系統(tǒng)的需求規(guī)格說明,導(dǎo)出一組與用戶模型和系統(tǒng)假想相協(xié)調(diào)的用戶任務(wù)。逐步求精和面向?qū)ο蠓治龅燃夹g(shù)同樣適用于任務(wù)分析。逐步求精技術(shù)可把任務(wù)不斷劃分為子任務(wù),直至對每個任務(wù)的要求都十分清楚;而采用面向?qū)ο蠓治黾夹g(shù)可識別出與應(yīng)用有關(guān)的所有客觀的對象以及與對象關(guān)聯(lián)的動作?紤]界面設(shè)計中的典型問題設(shè)計任何一個機(jī)界面,一般必須考慮系統(tǒng)響應(yīng)時間、用戶求助機(jī)制、錯誤信息處理和命令方式四個方面。應(yīng)當(dāng)由其它觸點(diǎn)擔(dān)任(例如油開關(guān)的輔助觸點(diǎn))。b.動斷主觸點(diǎn)性能直流有感(τ=5ms)回路,U≤250V,I≤0.5A,為50W;交流(cosФ=0.4)回路;U≤250V,I≤2A,為250VA。如果被控電路系由變流器供電并與繼電器主觸點(diǎn)并聯(lián),且當(dāng)電流為4A時,其總阻抗不大于4Ω,則繼電器的主觸點(diǎn)在電流不大于50A情況下能夠?qū)⑦@個電路分流接通與分流斷開。c.過渡轉(zhuǎn)換主觸點(diǎn)性能繼電器的過渡轉(zhuǎn)換主觸點(diǎn)控制電路由變流器供電,且其阻抗值在電流為3.5A時不大于4.5Ω,當(dāng)電流增至150A時,繼電器主觸點(diǎn)能夠?qū)⑦@個電路分流接通與分流斷開。d.信號觸點(diǎn)性能繼電器的動合信號觸點(diǎn),在電壓不大于250V時能接通或斷開電流不大于0.2A的直流無感電路或電流不大于0.5A交流電路。
No
|
Images
|
Model
|
Safety
|
DATA
|
Vin
|
Vout
|
Iout
|
Outputs
|
Price
|
Status
|
59
|
|
PTD25-24-1515
|

|
|
18 ~ 36V
|
+15V / -15V
|
0.80A/0.80A
|
dual
|
$34.73
|
Sale
|
58
|
|
PTS25-72-24
|
|
|
50 ~ 100V
|
24V
|
1.5A
|
single
|
$36.00
|
Call
|
57
|
|
PT25-48-5FF
|

|
|
36 ~ 72V
|
+5V / +15V / -15V
|
3.50A / 0.25A / 0.25A
|
triple
|
$35.18
|
Call
|
56
|
|
PT25-48-3FF
|

|
|
36 ~ 72V
|
+3.3V / +15V / -15V
|
3.50A / 0.28A / 0.28A
|
triple
|
$35.18
|
Call
|
55
|
|
PT25-48-522
|

|
|
36 ~ 72V
|
+5V / +12V / -12V
|
3.50A / 0.35A / 0.35A
|
triple
|
$35.18
|
Call
|
54
|
|
PT25-48-322
|

|
|
36 ~ 72V
|
+3.3V / +12V / -12V
|
3.50A / 0.35A / 0.35A
|
triple
|
$35.18
|
Sale
|
53
|
|
PTD25-48-1515
|

|
|
36 ~ 72V
|
+15V / -15V
|
0.80A / 0.80A
|
dual
|
$34.45
|
Call
|
52
|
|
PTD25-48-1212
|

|
|
36 ~ 72V
|
+12V / -12V
|
1.00A / 1.00A
|
dual
|
$34.45
|
Call
|
51
|
|
PTD25-48-55
|

|
|
36 ~ 72V
|
+5V / -5V
|
2.50A / 2.50A
|
dual
|
$34.45
|
Sale
|
50
|
|
PTS25-48-15
|

|
|
36 ~ 72V
|
15V
|
1.60A
|
single
|
$33.55
|
Call
|
49
|
|
PTS25-48-12
|

|
|
36 ~ 72V
|
12V
|
2.00A
|
single
|
$33.55
|
Call
|
48
|
|
PTS25-48-5
|

|
|
36 ~ 72V
|
5V
|
5.00A
|
single
|
$33.55
|
Call
|
47
|
|
PTS25-48-3R3
|

|
|
36 ~ 72V
|
3.3V
|
6.00A
|
single
|
$33.55
|
Sale
|
46
|
|
PT25-24-5FF
|

|
|
18 ~ 36V
|
+5V / +15V / -15V
|
3.50A / 0.25A / 0.25A
|
triple
|
$34.09
|
Sale
|
45
|
|
PT25-24-3FF
|

|
|
18 ~ 36V
|
+3.3V / +15V / -15V
|
3.50A / 0.28A / 0.28A
|
triple
|
$34.09
|
Term
|
44
|
|
PT25-24-522
|

|
|
18 ~ 36V
|
+5V / +12V / -12V
|
3.50A / 0.35A / 0.35A
|
triple
|
$34.09
|
Sale
|
43
|
|
PT25-24-322
|

|
|
18 ~ 36V
|
+3.3V / +12V / -12V
|
3.50A / 0.35A / 0.35A
|
triple
|
$34.09
|
Call
|
42
|
|
PTD25-24-1212
|

|
|
18 ~ 36V
|
+12V / -12V
|
1.00A / 1.00A
|
dual
|
$34.73
|
Sale
|
41
|
|
PTD25-24-55
|

|
|
18 ~ 36V
|
+5V / -5V
|
2.50A / 2.50A
|
dual
|
$34.73
|
Sale
|
40
|
|
PTS25-24-15
|

|
|
18 ~ 36V
|
15V
|
1.60A
|
single
|
$33.09
|
Sale
|
如果柵極上的噪聲電壓超過VGT,并有足夠的柵電流激發(fā)可控硅(晶閘管)內(nèi)部的正反饋,則也會被觸發(fā)導(dǎo)通。應(yīng)用安裝時,首先要使柵極外的連線盡可能短。當(dāng)連線不能很短時,可用絞線或屏蔽線來減小干擾的侵入。在然后G與MT1之間加一個1KΩ的電阻來降低其靈敏度,也可以再并聯(lián)一個100nf的電容,來濾掉高頻噪聲。關(guān)于轉(zhuǎn)換電壓變化率當(dāng)驅(qū)動一個大的電感性負(fù)載時,在負(fù)載電壓和電流間有一個很大的相移。當(dāng)負(fù)載電流過零時,雙向可控硅(晶閘管)開始換向,但由于相移的關(guān)系,電壓將不會是零。所以要求可控硅(晶閘管)要迅速關(guān)斷這個電壓。如果這時換向電壓的變化超過允許值時,就沒有足夠的時間使結(jié)間的電荷釋放掉,而被迫使雙向可控硅(晶閘管)回到導(dǎo)通狀態(tài)。即上電試機(jī)。在上電前后必須注意以下幾點(diǎn):上電之前,須確認(rèn)輸入電壓是否有誤,將380V電源接入220V級變頻器之中會出現(xiàn)炸機(jī)(炸電容、壓敏電阻、模塊等);檢查變頻器各接插口是否已正確連接,連接是否有松動,連接異常有時可能會導(dǎo)致變頻器出現(xiàn)故障,嚴(yán)重時會出炸機(jī)等情況;上電后檢測故障顯示內(nèi)容,并初步斷定故障及原因;如未顯示故障,首先檢查參數(shù)是否有異常,并將參數(shù)復(fù)歸后,在空載(不接電機(jī))情況下啟動變頻器,并測試U、V、W三相輸出電壓值。如出現(xiàn)缺相、三相不平衡等情況,則模塊或驅(qū)動板等有故障;在輸出電壓正常(無缺相、三相平衡)的情況下,負(fù)載測試,盡量是滿負(fù)載測試。[1]故障判斷整流模塊損壞通常是由于電網(wǎng)電壓或內(nèi)部短路引起。